Safe Fire Detection Products
|
What is Air Sampling Fire Detection? |
|
|
|
Air Sampling, also know as aspirating, fire detection utilizes an aspirator, and a supervised sample pipe network to return air samples from an environment that is being protected, back to a detection unit for analysis. The air sample is drawn into the pipe network through either holes drilled in the pipe, a capillary or extended drop from the pipe, or sample heads which can be either adjustable or non-adjustable. Each of these methods use flow calculations to determine sample hole sizes, pressure drops and acceptable pipe lengths to be sure the system meets NFPA guidelines. Below are details for each of these methods |
|
Hybrid Air Sampling DetectorsWhy ProSeries? |
||
|
The new advanced CCD (Cloud Chamber Detection) technology from Protec combines the benefits of spot, laser, and cloud chamber detection into a single detector. Unlike laser and conventional systems, ProSeries detectors using CCD technology only detect combustion. CCD technology is immune to false alarms from dirt, dust, temperature and humidity which plague other early warning air sampling and spot detectors. |
||
![]() |
• Before Smoke
• No False Alarms • Detects in All Four Stages of Fire
*Obscuration (obs/ft) - Percentage of light decrease per
foot |
|
|
|
|
![]() |
|
Linear Heat Detection (LHD) is a line-type form of fixed temperature heat detection used in common commercial and industrial environments. This linear cable can detect a fire anywhere along its entire length and is available in multiple temperatures. Why ThermoCable? • Addressable or Conventional • Up to 10,000 ft./zone • Use with Any New or Existing Panel • Lower Cost • Upgrade Existing Systems
ThermoCable |
|
What is Portable Aspirating Fire Detection? |
|
|
|
Portable
Aspirating Fire Detection is used to locate the source of an
early warning alarm. Any aspirating or spot detection
system can tell you which room, now the ProLocator can help
you find where in the room! |
|
![]() |
|
What is Cryogenic Gas Leak Detection? |
|
|
|
The ThermoCable LNG Cryogenic Gas Leak Detection System is specifically designed to offer the only high sensitivity and cost effective solution for protecting any compressed gas storage tanks, equipment, and pipelines from a potentially catastrophic fire or explosion. The system consists of a nylon coated ultra-sensitive detection cable and interface module. The ThermoCable LNG Interface Module and detection cable can be easily connected to, and powered by, any fire alarm control panel or building management system.
• Lower Cost • Flexible for Easy Installation • Self Restoring • Universal Interface Works with Any Panel or DCS • Nylon Coated for UV Protection • Intrinsically Safe Circuitry • 4-20mA and 0-10VDC Analog Outputs
|
|
|